Proper message id checks. Some refactoring for common code in rtcv2service handlers. Instantiate signalling based on synchronous local candidates flag, but needs better defined code.
142 lines
4.2 KiB
Go
142 lines
4.2 KiB
Go
// Copyright 2023 LiveKit, Inc.
|
|
//
|
|
// Licensed under the Apache License, Version 2.0 (the "License");
|
|
// you may not use this file except in compliance with the License.
|
|
// You may obtain a copy of the License at
|
|
//
|
|
// http://www.apache.org/licenses/LICENSE-2.0
|
|
//
|
|
// Unless required by applicable law or agreed to in writing, software
|
|
// distributed under the License is distributed on an "AS IS" BASIS,
|
|
// WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
|
|
// See the License for the specific language governing permissions and
|
|
// limitations under the License.
|
|
|
|
package signalling
|
|
|
|
import (
|
|
"fmt"
|
|
|
|
"github.com/livekit/protocol/livekit"
|
|
"github.com/livekit/protocol/logger"
|
|
protosignalling "github.com/livekit/protocol/signalling"
|
|
"google.golang.org/protobuf/proto"
|
|
|
|
"github.com/livekit/livekit-server/pkg/rtc/types"
|
|
|
|
"go.uber.org/atomic"
|
|
)
|
|
|
|
var _ ParticipantSignalHandler = (*signalhandlerv2)(nil)
|
|
|
|
type SignalHandlerv2Params struct {
|
|
Logger logger.Logger
|
|
Participant types.LocalParticipant
|
|
Signalling ParticipantSignalling
|
|
}
|
|
|
|
type signalhandlerv2 struct {
|
|
signalhandlerUnimplemented
|
|
|
|
params SignalHandlerv2Params
|
|
|
|
// SIGNALLING-V2-TODO: have to set this properly for `ConnectRequest` coming via sync HTTP path
|
|
lastProcessedRemoteMessageId atomic.Uint32
|
|
signalReassembler *protosignalling.SignalReassembler
|
|
}
|
|
|
|
func NewSignalHandlerv2(params SignalHandlerv2Params) ParticipantSignalHandler {
|
|
return &signalhandlerv2{
|
|
params: params,
|
|
signalReassembler: protosignalling.NewSignalReassembler(protosignalling.SignalReassemblerParams{
|
|
Logger: params.Logger,
|
|
}),
|
|
}
|
|
}
|
|
|
|
func (s *signalhandlerv2) HandleRequest(msg proto.Message) error {
|
|
req, ok := msg.(*livekit.Signalv2WireMessage)
|
|
if !ok {
|
|
s.params.Logger.Warnw(
|
|
"unknown message type", nil,
|
|
"messageType", fmt.Sprintf("%T", msg),
|
|
)
|
|
return ErrInvalidMessageType
|
|
}
|
|
|
|
// SIGNALLING-V2-TODO: check if this makes sense for data channel based signalling
|
|
s.params.Participant.UpdateLastSeenSignal()
|
|
|
|
switch msg := req.GetMessage().(type) {
|
|
case *livekit.Signalv2WireMessage_Envelope:
|
|
for _, clientMessage := range msg.Envelope.ClientMessages {
|
|
sequencer := clientMessage.GetSequencer()
|
|
if sequencer == nil || sequencer.MessageId == 0 {
|
|
s.params.Logger.Warnw(
|
|
"skipping message without sequencer", nil,
|
|
"messageType", fmt.Sprintf("%T", clientMessage),
|
|
)
|
|
continue
|
|
}
|
|
|
|
lprmi := s.lastProcessedRemoteMessageId.Load()
|
|
if sequencer.MessageId <= lprmi {
|
|
s.params.Logger.Infow(
|
|
"duplicate in message stream",
|
|
"last", lprmi,
|
|
"current", clientMessage.Sequencer.MessageId,
|
|
)
|
|
continue
|
|
}
|
|
|
|
// SIGNALLING-V2-TODO: ask for replay if there are gaps
|
|
if lprmi != 0 && sequencer.MessageId != lprmi+1 {
|
|
s.params.Logger.Infow(
|
|
"gap in message stream",
|
|
"last", lprmi,
|
|
"current", clientMessage.Sequencer.MessageId,
|
|
)
|
|
}
|
|
|
|
switch payload := clientMessage.GetMessage().(type) {
|
|
case *livekit.Signalv2ClientMessage_PublisherSdp:
|
|
s.params.Participant.HandleOffer(protosignalling.FromProtoSessionDescription(payload.PublisherSdp))
|
|
|
|
case *livekit.Signalv2ClientMessage_SubscriberSdp:
|
|
s.params.Participant.HandleAnswer(protosignalling.FromProtoSessionDescription(payload.SubscriberSdp))
|
|
|
|
case *livekit.Signalv2ClientMessage_Trickle:
|
|
candidateInit, err := protosignalling.FromProtoTrickle(payload.Trickle)
|
|
if err != nil {
|
|
s.params.Logger.Warnw("could not decode trickle", err)
|
|
return err
|
|
}
|
|
s.params.Participant.AddICECandidate(candidateInit, payload.Trickle.Target)
|
|
}
|
|
|
|
s.lastProcessedRemoteMessageId.Store(sequencer.MessageId)
|
|
s.params.Signalling.AckMessageId(sequencer.LastProcessedRemoteMessageId)
|
|
s.params.Signalling.SetLastProcessedRemoteMessageId(sequencer.MessageId)
|
|
}
|
|
|
|
case *livekit.Signalv2WireMessage_Fragment:
|
|
bytes := s.signalReassembler.Reassemble(msg.Fragment)
|
|
if len(bytes) != 0 {
|
|
wireMessage := &livekit.Signalv2WireMessage{}
|
|
err := proto.Unmarshal(bytes, wireMessage)
|
|
if err != nil {
|
|
s.params.Logger.Warnw("could not unmarshal re-assembled packet", err)
|
|
return err
|
|
}
|
|
|
|
s.HandleRequest(wireMessage)
|
|
}
|
|
}
|
|
|
|
return nil
|
|
}
|
|
|
|
func (s *signalhandlerv2) PruneStaleReassemblies() {
|
|
s.signalReassembler.Prune()
|
|
}
|