A couple of stream allocator tweaks (#1628)

* A coupke of stream allocator tweaks

- Do not overshoot on catch up. It so happens that during probe
  the next higher layer is at some bit rate which is much lower
  than normal bit rate for that layer. But, by the time the probe
  ends, publisher has climbed up to normal bit rate.
  So, the probe goal although achieved is not enough.
  Allowing overshoot latches on the next layer which might be more
  than the channel capacity.
- Use a collapse window to record values in case of a only one
  or two changes in an evaluation window. Some times it happens
  that the estimate falls once or twice and stays there. By collapsing
  repeated values, it could be a long time before that fall in estimate
  is processed. Introduce a collapse window and record duplicate value
  if a value was not recorded for collapse window duration. This allows
  delayed processing of those isolated falls in estimate.

* minor clean up

* add a probe max rate

* fix max

* use max of committed, expected for max limiting

* have to probe at goal
This commit is contained in:
Raja Subramanian
2023-04-18 11:49:51 +05:30
committed by GitHub
parent 5b34d754e0
commit 93604d2415
4 changed files with 69 additions and 33 deletions
+31 -4
View File
@@ -37,7 +37,7 @@ type TrendDetectorParams struct {
Logger logger.Logger
RequiredSamples int
DownwardTrendThreshold float64
CollapseValues bool
CollapseThreshold time.Duration
}
type TrendDetector struct {
@@ -49,6 +49,9 @@ type TrendDetector struct {
lowestValue int64
highestValue int64
hasFallen bool
lastSampleAt time.Time
direction TrendDirection
}
@@ -66,6 +69,8 @@ func (t *TrendDetector) Seed(value int64) {
}
t.values = append(t.values, value)
t.lastSampleAt = time.Now()
t.hasFallen = false
}
func (t *TrendDetector) AddValue(value int64) {
@@ -77,10 +82,32 @@ func (t *TrendDetector) AddValue(value int64) {
t.highestValue = value
}
// ignore duplicate values
if t.params.CollapseValues && len(t.values) != 0 && t.values[len(t.values)-1] == value {
return
// Ignore duplicate values in collapse window.
//
// Bandwidth estimate is received periodically. If the estimate does not change, it will be repeated.
// When there is congestion, there are several estimates received with decreasing values.
//
// Using a sliding window, collapsing repeated values and waiting for falling trend is to ensure that
// the reaction is not too fast, i. e. reacting to falling values too quick could mean a lot of re-allocation
// resulting in layer switches, key frames and more congestion.
//
// But, on the flip side, estimate could fall once or twice withing a sliding window and stay there.
// In those cases, using a collapse window to record value even if it is duplicate. By doing that,
// a trend could be detected eventually. If will be delayed, but that is fine with slow changing estimates.
lastValue := int64(0)
if len(t.values) != 0 {
lastValue = t.values[len(t.values)-1]
}
if lastValue == value && t.params.CollapseThreshold > 0 {
if !t.hasFallen || (!t.lastSampleAt.IsZero() && time.Since(t.lastSampleAt) < t.params.CollapseThreshold) {
return
}
}
if lastValue > value {
t.hasFallen = true
}
t.lastSampleAt = time.Now()
if len(t.values) == t.params.RequiredSamples {
t.values = t.values[1:]