Rollover sequence number when time stamp is moving forward. (#2876)
* Rollover sequence number when time stamp is moving forward. Seeing large gaps in sequence number due to potential network issues. In that gap, the sequence number could roll over. Using packet time jumps to figure out if a roll over could have happened and force roll over the sequence number to ensure that it does not flow backwards. * fix test
This commit is contained in:
@@ -190,7 +190,7 @@ func Test_RTPStatsReceiver_Update(t *testing.T) {
|
||||
require.Equal(t, uint64(9), r.packetsLost)
|
||||
|
||||
// out-of-order should decrement number of lost packets
|
||||
packet = getPacket(sequenceNumber-6, timestamp-45000, 1000)
|
||||
packet = getPacket(sequenceNumber-6, timestamp-18000, 1000)
|
||||
flowState = r.Update(
|
||||
time.Now().UnixNano(),
|
||||
packet.Header.SequenceNumber,
|
||||
|
||||
Reference in New Issue
Block a user